• Home
  • Flow measurement

Flow measurement-old

Four-path Gas Ultrasonic Flow Meter Senior Sonic 3414
gas usm 3414
SPECIFICATIONS
Velocity Range: 
  Nominal 0 to 30 m/s (0 to 100 fp/s) with over-range
  performance exceeding 38 m/s (125 fp/s) on some size
Meter Performance: 
  Flow calibrated accuracy is ±0.1% of reading relative to lab
  over entire flow calibration range
Repeatability: ±0.05% of reading for 1.5 to 30.5 m/s
Line Sizes: 100 to 1050 mm (4 to 42 in)
Operating Pressure Range (Transducers): 689 to 27,579 kPa (100 to 4,000 psig)
Operating Temperature: -40°C to +60°C (-40°F to +140°F)
Power: 10.4 VDC to 36 VDC
Certifications: Explosive Atmospheres (ATEX)
Certifications: MID, TCM

For more information >>> Product Data SheetProduct Data Sheet
Floboss103

Floboss 103
Floboss103
SPECIFICATIONS
Mass flow accuracy: ±0,075% of span
Rangedown:
differential pressure: 10:1
absolute pressure: 5:1
Stability: ±0,1% of URL for 12 months
Pressure ranges:
differential pressure: 0 to 62,2 kPa
absolute pressure: 0 to 25 MPa
Temperature process fluids: -40°C to 85°C
Output: 4-20 mA - RS 232 or RS 485
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
Floboss103

Vortex 8800D
Vortex8800D
SPECIFICATIONS
Mass flow accuracy:
for liquid: ±0,65% of flow rate
for gas and steam: ±1,35% of rate
Stability: ±0,1% of URL for 12 months
Repeatability: ±0,1%
Process connection:
ANSI: Class 150 - Class 1500
DIN: PN16 - PN160
JIS: 10K - 40K
Temperature process fluids: -40°C to 454°C
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
Vortex8800D

3051SFC
3051_SFC
SPECIFICATIONS
Mass flow accuracy: ±0,75% of flow rate
Stability: 5 years
Rangedown: 8:1
Repeatability: ±0,1%
Immersion lenght: 15 mm - 200 mm
Temperature process fluids: to 454°C
Process connection:
ANSI: Class 150 - Class 600
DIN: PN16 - PN100
JIS: 10K - 40K
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
3051_SFC

3051SFA
3051SFA
SPECIFICATIONS
Mass flow accuracy: ±0,9% of flow rate
Rangedown: 8:1
Mass flow repeatability: ±0,1%
Immersion lenght: 50 mm - 1800 mm
Temperature process fluids: -40°C to 454°C
Process connection:
ANSI: Class 150 - Class 2500
DIN: PN16 - PN100
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
3051 SFA

3095MFA
3095_MFA
SPECIFICATIONS
Mass flow accuracy: ±0,9% of flow rate
Rangedown: 8:1
Mass flow repeatability: ±0,1%
Immersion lenght: 50 mm - 2400 mm
Temperature process fluids: -40°C to 454°C
Process connection:
ANSI: Class 150 - Class 2500
DIN: PN16 - PN100
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
3095 MFA

Annubar285 Annubar 285

SPECIFICATIONS
Mass flow accuracy:
for liquids: ±1,0% of flow rate
for gas and steam: ±2,0% of flow rate
Rangedown: 10:1
Mass flow repeatability: ±0,1%
Immersion lenght: 50 mm - 2400 mm
Temperature process fluids: -40°C to 149°C



For more information >>> Product Data SheetProduct Data Sheet
Annubar285
Annubar485
Annubar 485

SPECIFICATIONS
Mass flow accuracy: ±0,75% of flow rate
Rangedown: 10:1
Mass flow repeatability: ±0,1%
Immersion lenght: 50 mm - 2400 mm
Temperature process fluids: -40°C to 677°C
Process connection:
ANSI: Class 150 - Class 2500
DIN: PN16 - PN100

For more information >>> Product Data SheetProduct Data Sheet
Annubar 485

Magnetic Flowmeter 8705
Magnetic Flowmeter 8705
SPECIFICATIONS
Accuracy: ±0,5% of rate
Flow rate range: 0,3 to 10 m/s
Compatibility:
with Rosemount 8712D, 8732E and 8742C transmitters
Line sizes: 15 mm - 900 mm
Temperature process fluids: -29°C to 177°C
Ambient temperature limits: -34°C to 65°C
Odolnost proti ponoření: to 10 meters, IP 68
Process connection:
ANSI: Class 150 - Class 300
DIN: PN10- PN40

For more information >>> Product Data SheetProduct Data Sheet
Magnetic Flowmeter 8705

Magnetic Flowmeter 8707
Magnetic Flowmeter 8707
SPECIFICATIONS
Accuracy: ±0,5% of rate
Flow rate range: 1 to 10 m/s
Compatibility:
with Rosemount 8712D/H, 8732E and 8742C transmitters
Line sizes: 80 mm - 600 mm
Temperature process fluids: -29°C to 177°C
Ambient temperature limits: -34°C to 65°C
Odolnost proti ponoření: to 10 meters, IP 68
Process connection:
ANSI: Class 150 - Class 900
DIN: PN10 - PN40

For more information >>> Product Data SheetProduct Data Sheet
Magnetic Flowmeter 8707

Magnetic Flowmeter 8711
Magnetic Flowmeter 8711
SPECIFICATIONS
Accuracy: ±0,5% of rate
Flow rate range: 1 to 10 m/s
Compatibility:
with Rosemount 8712D, 8732E and 8742C transmitters
Line sizes: 15 mm to 200 mm
Temperature process fluids: -29°C to 149°C
Ambient temperature limits: -34°C to 65°C
Process connections:
ANSI: Class 150 to Class 300
DIN: PN10 and PN25

For more information >>> Product Data SheetProduct Data Sheet
Magnetic Flowmeter 8711

Magnetic Flowmeter 8721
Magnetic Flowmeter 8721 (Sanitary Flowtube)

SPECIFICATIONS
Accuracy: ±0,5% of rate
Stability: ±0,1% of rate over 6 months
Repeatability: ±0,1% of reading
Flow rate range: 0,01 to 12 m/s
Compatibility:
with Rosemount 8712D, 8732E and 8742C transmitters
Line sizes: 15 mm - 100 mm
Temperature process fluids: -29°C to 177°C
Ambient temperature limits: -15°C to 60°C
Process connections:
Tri-Clamp (Sanitary Coupling), Weld Nipple, DIN 11851, DIN 11864, SMS 1145

For more information >>> Product Data SheetProduct Data Sheet
Magnetic Flowmeter 8721

Transmitter 8712D/H
Transmitter 8712D/H
SPECIFICATIONS
Flowtube coil resistance:
8712D: 350 Ohm
8712H: 12 Ohm
Flow rate range:
8712D: 0 to 12 m/s
8712H: 0,01 to 10 m/s
Stability: ±0,1% of rate over 6 months
Repeatability: ±0,1% of reading
Compatibility:
8712D: with Rosemount 8705, 8707, 8711 and 8721
8712H: only with Rosemount 8707
Ambient temperature limits:
8712D: -29°C to 60°C
8712H: -29°C to 54°C

For more information >>> Product Data SheetProduct Data Sheet
Transmitter 8712D/H

Transmitter 8732E/8742C
Transmitter 8732E­/8742C
SPECIFICATIONS
Flowtube coil resistence: 25 Ohm maximum
Flow rate range:
8732E: 0,01 to 10 m/s
8742C: 0 to 12 m/s
Stability: ±0,1% of rate over 6 months
Repeatability: ±0,1% of reading
Compatibility:
with Rosemount 8705, 8711 and 8721
Ambient temperature limits: -40°C to 74°C

For more information >>> Product Data SheetProduct Data Sheet
Transmitter 8732E/8742C

Transmitter RFT9739
Transmitter RFT9739
SPECIFICATIONS
works with Micro Motion senzors:
H, F, ELITE
Output:
4 - 20 mA + HART or Modbus
frequency output (active 0 to 15V, pasive 0 to 30V)
Dual-channel frequency output
Communication:
Bell 202
RS-485
Isolation:
vstupu i výstupu

For more information >>> Product Data SheetProduct Data Sheet
Transmitter RFT9739

Transmitter series 1000 and 2000
Transmitter series 1000 and 2000
SPECIFICATIONS
works with Micro Motion senzors:
R, F, T, ELITE
Compact control:
integral mounting to sensor
sensor with 360 degrees of rotation
Dual line display for process variables and totalizer reset
Ambient temperature limits:
8712D: -40°C to 55°C
Output:
4 - 20 mA + HART, Fieldbus or Modbus
Frequency/pulse output
RS-485

For more information >>> Product Data SheetProduct Data Sheet
Transmitter series 1000 and 2000

Transmitter series 3000

Převodník série 3000 SPECIFICATIONS
works with Micro Motion senzors:
R, T, H, F, ELITE
Large operator interface for easy setup & control:
128 x 128 pixel display enhances view of process
Easy to read menus and advanced help system
Transmitter and discrete control from a single instrument:
4 - 20 mA + HART or Fieldbus
Functions as an advanced process transmitter
As a discrete batch controller, with 8 I/O channels for maximum adaptability
Wide variety of applications:
Concentration & net flow measurement
Custody transfer with batch control
Patented meter verification application

For more information >>> Product Data SheetProduct Data Sheet
Transmitter series 3000

LF-senzor

LF-senzor SPECIFICATIONS
Maximum flow range: 27 kg/h
Mass flow accuracy:
for liquid: ±0,5%
for gas: ±0,5%
Density accuracy: ±0,3%
Mass flow repeatability:
for liquid: ±0,5%
for gas: ±0,5%
Temperature rating: 0°C to 65°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
LF-senzor

R-senzor R-senzor

SPECIFICATIONS
Maximum flow range: 87 100 kg/h
Mass flow accuracy:
for liquid: ±0,50%
for gas: ±0,75%
Mass flow repeability:
for liquid: ±0,25%
for gas: ±0,50%
Temperature rating: -50°C to 150°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
R-senzor
T-senzor
T-senzor

SPECIFICATIONS
Maximum flow range: 87 100 kg/h
Mass flow accuracy:
for liquid: ±0,15%
for gas: ±0,5%
Density accuracy: ±2,0kg/m3
Mass flow repeatability: ± 0,05%
Temperature rating: -50°C to 150°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
T-senzor

H-senzor H-senzor

SPECIFICATIONS
Maximum flow range: 272 160 kg/h
Mass flow accuracy:
for liquid: ±0,15%
pro gas: ±0,50%
Mass flow accuracy: ±2,0kg/m3
Mass flow repeatability:
for liquid: ±0,10%
for gas: ±0,25%
Temperature rating: -100°C to 180°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
H-senzor

F-senzor F-senzor

SPECIFICATIONS
Maximum flow range: 272 160 kg/h
Mass flow accuracy:
for liquid: ±0,20%
for gas: ±0,50%
density accuracy: ±2,0kg/m3
Rangedown: 20:1
Mass flow repeatability:
for liquid: ±0,10%
for gas: ±0,25%
Temperature rating: -100°C to 180°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
F-senzor

ELITE/CMF
ELITE/CMF
SPECIFICATIONS
Maximum flow range: 545 500 kg/h
Mass flow accuracy:
for liquid: ±0,10%
for gas: ±0,35%
density accuracy: ±0,5kg/m3
Mass flow repeatability:
for liquid: ±0,05%
for gas: ±0,25%
Temperature rating: -240°C to 204°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet

 