Pressure measurement

  • Series 3051S Pressure measurement - SPECIFICATIONS 3051S CD/CG/CA
  • Accuracy: Classic: ±0,055% of span | Ultra: ±0,025% of span
  • Stability: 10 years
  • Rangetown: 200:1
  • Pressure range: CD: -13,8 MPa to 13,8 MPa | CG: -97,9 kPa to 13,8 MPa | CA: 1,2 kPa to 27,6 MPa
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: 41 MPa
  • Certifications: SIS, Atex
  • Data sheet - pdf3051S

  • Series 3051S Pressure measurement - SPECIFICATIONS 3051S T
  • Accuracy: Classic: ±0,055% of span | Ultra: ±0,025% of span
  • Stability: 10 years
  • Rangetown: 200:1
  • Pressure range: 2 kPa to 69 MPa
  • Number of ranges: 5
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: 103 MPa
  • Certifications: SIS, Atex
  • Data sheet - pdf3051S

  • Series 3051 Pressure measurement - SPECIFICATIONS 3051 CD/CG/CA
  • Accuracy: 3051SCD/CG: ±0,065% of span | CA: ±0,075% of span
  • Stability: 10 years
  • Rangetown: 100:1
  • Pressure range: CD: -13,8 MPa to 13,8 MPa | CG: 3,45 kPa abs. to 13,8 MPa | CA: 2 kPa to 27,6 MPa
  • Number of ranges: 6
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C (HD: 191°C)
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: CD/CG: 31 MPa | CA: 41 MPa
  • Certifications: Atex
  • Data sheet - pdf3051

  • Series 3051 Pressure measurement - SPECIFICATIONS 3051 HD/HG
  • Accuracy: ±0,075% of span
  • Stability: ±±0,2% of URL for 12 months
  • Rangetown: 100:1
  • Pressure range: HD: -13,8 MPa to 13,8 MPa | HG: 3,45 kPa abs. to 13,8 MPa
  • Number of ranges: 6
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C (HD: 191°C)
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: 25 MPa
  • Certifications: Atex
  • Data sheet - pdf3051

  • Series 3051 Pressure measurement - SPECIFICATIONS 3051 T
  • Accuracy: ±0,04% of span
  • Stability: ±0,125% of URL for 5 years
  • Rangetown: 100:1
  • Pressure range: TG: -101 kPa to 68,9 MPa | TA: 2,07 kPa to 68,9 MPa
  • Number of ranges: 5
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: 103 MPa
  • Certifications: Atex
  • Data sheet - pdf3051

  • Series 2051 Pressure measurement - SPECIFICATIONS 2051 CD/CG
  • Accuracy: ±0,075% of span (optional 0,065%)
  • Stability: 2051C range 2-5 ±0,1% of URL for 2 years | (optional ±0,125% of URL for 5 years kód-P8) | 2051CD range 1 ±0,2% of URL for 1 roku
  • Rangetown: 100:1
  • Pressure range: CD: -13,79 MPa - 13,79 MPa | CG: -98 kPa - 13,79 MPa
  • Number of ranges: 5
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C (coplanar collar, cartridge D.C. Silicone)
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: range 1 13,79 MPa | range 2-5 25 MPa ( optional 31 MPa kód-P9)
  • Certifications: Atex
  • Data sheet - pdf2051

  • Series 2051 Pressure measurement - SPECIFICATIONS  2051 T
  • Accuracy: ±0,075% of span (optional 0,065%)
  • Stability: 2051C range 2-5 ±0,1% of URL for 2 years | (optional ±0,125% of URL for 5 years kód-P8)
  • Rangetown: 100:1
  • Pressure range: TA: 0 kPa to 68,9 MPa | TG: -101 kPa to 68,9 MPa
  • Number of ranges: 5
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C (coplanar collar, cartridge D.C. Silicone)
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: range-1 5,17 MPa | range-2 10,34 MPa | range-3 11,03 MPa | range-4 41,37 MPa | range-5 103,42 MPa
  • Certifications: Atex
  • Data sheet - pdf2051

  • Series 2088 Pressure measurement - SPECIFICATIONS  2088
  • Accuracy: ±0,1% of span
  • Stability: ±0,1% of URL for 12 months
  • Rangetown: 20:1
  • Pressure range: 10 kPa - 27,6 MPa
  • Number of ranges: 4
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C
  • Output: 4-20 mA + HART
  • Overpressure limit: 55 MPa
  • Certifications: Atex
  • Data sheet - pdf2088

  • Pressure measurement - 4500 SPECIFICATIONS
  • Accuracy: ±0,065% of span
  • Stability: ±0,125% of URL for 5 years
  • Rangetown: 100:1
  • Pressure range: 2,1 kPa - 69 MPa
  • Number of ranges: 5
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +121°C
  • Output: 4-20 mA + HART
  • Overpressure limit: 103 MPa
  • Certifications: Atex
  • Data sheet - pdf4500

  • Pressure measurement - 4600 SPECIFICATIONS
  • Accuracy: ±0.25% of span
  • Stability: ±0,5% of span for 3 years
  • Rangetown: 40:1
  • Pressure range: 1,38 kPa - 137,9 MPa
  • Number of ranges: 4
  • Ambient temperature limit: -40°C to +85°C
  • Temperature process fluids: -40°C to +93°C
  • Output: 4-20 mA + HART
  • Overpressure limit: 165 MPa
  • Certifications: Atex
  • Data sheet - pdf4600

  • Rosemount 304R Conventional Manifold SPECIFICATIONS
  • Manifold Style: Traditional | Wafer
  • Manifold Type: 2-valve | 3-valve | 5-valve
  • Pressure Limits: PTFE Seal: 41,4 MPa | Grafit Seal: 41,4 MPa
  • Process connections:  1/2 - 14 Female NPT | Flanged
  • Data sheet - pdf304

  • Rosemount 305R Integral Manifold SPECIFICATIONS
  • Manifold Style: Coplanar | Traditional
  • Manifold Type: 2-valve | 3-valve | 5-valve
  • Pressure Limits: PTFE Seal: 68,9 MPa | Grafit Seal: 41,4 MPa
  • Process connections: 1/4 - 18 NPT Female | 1/2 - 14 Female NPT
  • Data sheet - pdf305

  • Rosemount 306RT Inline Manifold SPECIFICATIONS
  • Manifold Style: Threaded
  • Manifold Type: 1-valve | 2-valve
  • Pressure Limits: PTFE Seal: 68,9 MPa | Grafit Seal: 41,4 MPa
  • Process connections:  1/2 - 14 NPT Male | 1/2 - 14 Female NPT
  • Data sheet - pdf306