Flow measurement
- Four-path Gas Ultrasonic Flow Meter
SPECIFICATIONS Senior Sonic 3414
- Velocity Range: 0 to 30 m/s
- Meter Performance: Flow calibrated accuracy is ±0.1% of reading relative to lab over entire flow calibration range
- Repeatability: ±0,05% of reading for 1,5 to 30,5 m/s
- Line Sizes:100 to 1050 mm
- Operating Pressure Range (Transducers): 689 to 27,579 kPa-g
- Operating Temperature: -40°C to 60°C
- Power: 10.4 VDC to 36 VDC
- Certifications: Explosive Atmospheres (ATEX)
- Certifications: MID, TCM
- Data sheet - Gas USM 3414
- Flow measurement - SPECIFICATIONS - Floboss 103
- Mass flow accuracy: ±0,075% of span
- Stability: ±0,1% z URL for 12 months
- Rangetown: Differential pressure: 10:1 | Absolute pressure: 5:1
- Pressure ranges: Differential pressure: 0 - 62,2 kPa | Absolute pressure: 0 - 25 MPa
- Operating Temperature: -40°C to +85°C
- Output: 4-20 mA - RS 232 or RS 485
- Certifications: Atex
- Data sheet - Floboss103
- Flow measurement liquid (water) and gas - SPECIFICATIONS - Vortex 8800D
- Mass flow accuracy: for liquid: ±0,65% of flow rate | for gases and steam: ±1,35% of rate
- Stability: ±0,1% z URL for 12 months
- Repeatability: ±0,1%
- Pressure ranges: 2 kPa to 69 MPa
- Process connection: ANSI: Class 150 - Class 1500 | DIN: PN16 - PN160 | JIS: 10K - 40K
- Temperature process fluids: -40°C to 454°C
- Output: 4-20 mA + HART or Fieldbus
- Certifications: Atex
- Data sheet - Vortex8800D
- Flow measurement - SPECIFICATIONS - 3051SFC
- Mass flow accuracy: ±0,75% of flow rate
- Stability: 5 years
- Rangetown: 8:1
- Repeatability: ±0,1%
- Immersion lenght: 15 mm - 200 mm
- Temperature process fluids: to 454°C
- Process connection: ANSI: Class 150 - Class 600 | DIN: PN16 - PN100 | JIS: 10K - 40K
- Output: 4-20 mA + HART or Fieldbus
- Certifications: Atex
- Data sheet - 3051_SFC
- Flow measurement - SPECIFICATIONS - 3051SFA
- Mass flow accuracy: ±0,9% of flow rate
- Rangetown: 8:1
- Repeatability: ±0,1%
- Immersion lenght: 50 mm - 1800 mm
- Temperature process fluids: -40°C to 454°C
- Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
- Output: 4-20 mA + HART or Fieldbus
- Certifications: Atex
- Data sheet - 3051SFA
- Flow measurement - SPECIFICATIONS - 3095MFA
- Mass flow accuracy: ±0,9% of flow rate
- Rangetown: 8:1
- Repeatability: ±0,1%
- Immersion lenght: 50 mm - 2400 mm
- Temperature process fluids: -40°C to 454°C
- Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
- Output: 4-20 mA + HART or Fieldbus
- Certifications: Atex
- Data sheet - 3051MFA
- Flow measurement - SPECIFICATIONS - Annubar 485
- Mass flow accuracy: ±0,75% of flow rate
- Repeatability: ±0,1%
- Immersion lenght: 50 mm - 2400 mm
- Temperature process fluids: -40°C to 677°C
- Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
- Data sheet - Annubar485
- SPECIFICATIONS - Magnetic Flowmeter 8705
- Mass flow accuracy: ±0,5% of rate
- Flow rate range: od 0,3 to 10 m/s
- Rangetown: 8:1
- Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
- Line sizes: 15 mm - 900 mm
- Temperature process fluids: -29°C to 177°C
- Resistance to immersion: to 10 meters, IP 68
- Process connection: ANSI: Class 150 - Class 300 | DIN: PN10 - PN40
- Data sheet - 8700
- SPECIFICATIONS - Magnetic Flowmeter 8707
- Mass flow accuracy: ±0,5% of rate
- Flow rate range: od 1 to 10 m/s
- Rangetown: 8:1
- Compatibility: with Rosemount 8712D/H, 8732E and 8742C transmitters
- Line sizes: 80 mm - 600 mm
- Temperature process fluids: -29°C to 177°C
- Resistance to immersion: to 10 meters, IP 68
- Process connection: ANSI: Class 150 - Class 900 | DIN: PN10 - PN40
- Data sheet - 8700
- SPECIFICATIONS - Magnetic Flowmeter 8711
- Mass flow accuracy: ±0,5% of rate
- Flow rate range: od 1 to 10 m/s
- Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
- Line sizes: 15 mm - 200 mm
- Temperature process fluids: -29°C to 177°C
- Resistance to immersion: to 10 meters, IP 68
- Process connection: ANSI: Class 150 - Class 300 | DIN: PN10 - PN25
- Data sheet - 8700
- SPECIFICATIONS - Magnetic Flowmeter 8721 (Sanitary Flowtube)
- Mass flow accuracy: ±0,5% of rate
- Flow rate range: od 0,01 to 10 m/s
- Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
- Line sizes: 15 mm - 200 mm
- Temperature process fluids: -29°C to 177°C
- Resistance to immersion: to 10 meters, IP 68
- Process connection: Tri-Clamp (Sanitary Coupling) | Weld Nipple | DIN 11851 | DIN 11864 | SMS 1145
- Data sheet - 8700
- Transmitter - SPECIFICATIONS - 8712D/H
- Flowtube coil resistance: 8712D: 350 | Ohm 8712H: 12 Ohm
- Flow rate range: 8712D: 0 - 12 m/s | 8712H: 0,01 - 10 m/s
- Stability: ±0,1% of rate over 6 months
- Repeatability: ±0,1%
- Compatibility: 8712D: with Rosemount 8705, 8707, 8711 and 8721 | 8712H: only with Rosemount 8707
- Teplotní rozsah: 8712D: -29°C to 60°C | 8712D: -29°C to 60°C
- Data sheet - 8700
- Transmitter - SPECIFICATIONS - 8732E/8742C
- Flowtube coil resistence: 25 Ohm maximum
- Flow rate range: 8732E: 0,01 - 10 m/s | 8742C: 0 - 12 m/s
- Stability: ±0,1% of rate over 6 months
- Repeatability: ±0,1%
- Compatibility: with Rosemount 8705, 8711 and 8721
- Temperature process fluids: -40°C to 74°C
- Data sheet - 8700
- Transmitter - SPECIFICATIONS - RFT9739
- Works with Micro Motion senzors: H, F, ELITE
- Output: 4 - 20 mA + HART or Modbus | equency output (active 0 to 15V, pasive 0 to 30V) | dDual-channel frequency output
- Communication: Bell 202 | RS-485
- Data sheet - RFT9739
- Transmitter - SPECIFICATIONS - série 1000 a 2000
- Works with Micro Motion senzors: R, F, T, ELITE
- Compact control: integral mounting to sensor | sensor with 360 degrees of rotation | Dual line display for process variables and totalizer reset
- Output: 4 - 20 mA + HARD, Fieldbus or Modbus | Frequency/pulse output | RS485
- Data sheet - 1000 a 2000
- Transmitter - SPECIFICATIONS - série 3000
- Works with Micro Motion senzors: R, T, H, F, ELITE
- Large operator interface for easy setup adn control: 128 x 128 pixel display enhances view of process
- Mass flow accuracy: for liquids: ±0,5% of flow rate | for gas: ±0,5% of flow rate | Density accuracy: ±0,3%
- Easy to read menus and advanced help system
- Output: 4 - 20 mA + HART or Fieldbus
- Data sheet - 3000
- Maximum flow range: 27 kg/h
- Mass flow accuracy: for liquids: ±0,5% of flow rate | for gas: ±0,5% of flow rate | Density accuracy: ±0,3%
- Repeatability: for liquids: ±0,5% | for gas: ±0,5%
- Temperature process fluids: 0°C to 65°C
- Certifications: Atex
- Data sheet - LF-senzor
- Maximum flow range: 87 100 kg/h
- Mass flow accuracy: for liquids: ±0,50% of flow rate | for gas: ±0,75% of flow rate
- Repeatability: for liquids: ±0,5% | for gas: ±0,5%
- Temperature process fluids: -50°C to 150°C
- Certifications: Atex
- Data sheet - R-senzor
- Maximum flow range: 87 100 kg/h
- Mass flow accuracy: for liquids: ±0,15% of flow rate | for gas: ±0,5% of flow rate | Density accuracy: ±2,0kg/m3
- Repeatability: ± 0,05%
- Temperature process fluids: -50°C to 150°C
- Certifications: Atex
- Data sheet - T-senzor
- Maximum flow range: 272 160 kg/h
- Mass flow accuracy: for liquids: ±0,15% of flow rate | for gas: ±0,50% of flow rate | Density accuracy: ±2,0kg/m3
- Repeatability: for liquids: ±0,10% | for gas: ±0,25%
- Temperature process fluids: -100°C to 180°C
- Certifications: Atex
- Data sheet - H-senzor
- Maximum flow range: 272 160 kg/h
- Mass flow accuracy: for liquids: ±0,20% of flow rate | for gas: ±0,50% of flow rate | Density accuracy: ±2,0kg/m3
- Rangetown: 20:1
- Repeatability: for liquids: ±0,10% | for gas: ±0,25%
- Temperature process fluids: -100°C to 180°C
- Certifications: Atex
- Data sheet - F-senzor
- Maximum flow range: 545 500 kg/h
- Mass flow accuracy: for liquids: ±0,10% of flow rate | for gas: ±0,35% of flow rate | Density accuracy: ±0,5kg/m3
- Repeatability: for liquids: ±0,05% | for gas: ±0,25%
- Temperature process fluids: -240°C to 204°C
- Certifications: Atex
- Data sheet - ELITE-CMF