- Series 3051S Pressure measurement - SPECIFICATIONS 3051S CD/CG/CA
- Accuracy: Classic: ±0,055% of span | Ultra: ±0,025% of span
- Stability: 10 years
- Rangetown: 200:1
- Pressure range: CD: -13,8 MPa to 13,8 MPa | CG: -97,9 kPa to 13,8 MPa | CA: 1,2 kPa to 27,6 MPa
- Ambient temperature limit: -40°C to +85°C
- Temperature process fluids: -40°C to +121°C
- Output: 4-20 mA + HART or Fieldbus
- Overpressure limit: 41 MPa
- Certifications: SIS, Atex
- Data sheet - 3051S