3051 L 3051 L

SPECIFICATIONS
Accuracy: ±0,075% of rate
Stability: ±0,125% of URL for 5 years
Rangedown: 100:1
Pressure range: 0,65 kPa - 2070 kPa
Počet rozsahů: 3
Ambient temperature: -40°C to +85°C
Temperature process fluids: -40°C to +121°C
Output: 4-20 mA + HART nebo Fieldbus
Overpressure limit: dle typu příruby
Certification: Atex

For more information >>> Product Data SheetProduct Data Sheet
3051 L

3051S L 3051S L

SPECIFICATIONS
Accuracy: ±0,065% of rate
Stability: 10 years
Rangedown: 100:1
Pressure range: 0,12 kPa - 13,8 MPa
Počet rozsahů: 5
Ambient temperature limit: -40°C to +85°C
Temperature process fluids: -40°C to +121°C
Output: 4-20 mA + HART nebo Fieldbus
Overpressure limit: dle typu příruby
Certifications: SIS, Atex

For more information >>> Product Data SheetProduct Data Sheet
Model 2051

2051 L

Model 2051 SPECIFIKACE
Accuracy: ±0,075% of span
Stability: ±0,125% of URL for 2 years
Rangedown: 100:1
Pressure range:
-62,2 kPa - 2068 kPa
Number of ranges: 3
Ambient temperature limit: -40°C do +85°C
Temperature process fluids: -40°C do +121°C
Output: 4-20 mA + HART or Fieldbus
Overpressure limit: meadly type of collar
Certificates: Atex

For more information >>> Product Data SheetProduct Data Sheet
3051S L

1151 LT 1151 LT

SPECIFICATIONS
Accuracy: ±0,25% of rate
Stability: ±0,25% of URL for 2 years
Rangedown: 50:1
Pressure range: 0,75 kPa - 690 kPa
Počet rozsahů: 3
Ambient temperature limit: -40°C to +85°C
Temperature process fluids: -40°C to +121°C
Output: 4-20 mA + HART or Fieldbus
Overpressure limit: 31 MPa
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
1151 LT

2110

2110 SPECIFICATIONS
Measurement Principle: Vibrating Fork
Maximum Operating Pressure: Final rating depends on tank connection
Minimum Liquid Density: 600 kg/m3
Liquid Viscosity Range: 0,2 to 10 000 cP
Switching Delay: 0,3; 1; 3; 10; 30 seconds
Electrical Connections:
Direct load switching: =21V to =264V and ~21V to ~264V (50 Hz/60 Hz)
Solid state PNP output: =18 V to =60 V
Process connection:
two wire
three wire
Temperature process fluids: -40°C to +150°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
2110

2120

SPECIFICATIONS
2120 Measurement Principle: Vibrating Fork
Maximum Operating Pressure: Final rating depends on tank connection
Minimum Liquid Density: 600 kg/m3
Liquid Viscosity Range: 0,2 to 10 000 cP
Switching Delay: 0,3; 1; 3; 10; 30 seconds
Electrical Connections:
Direct load switching: =20V to =60V and ~20V to ~264V (50 Hz/60 Hz)
Solid state PNP output: =20 V to =60 V
SPCO single relay: =Umax 60V and ~Umax 250V
Intrinsically Safe NAMUR
Process connection:
two wire
three wire
Temperature process fluids: -40°C to +150°C
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
2120

Float Level Sensor

Fieldvue SPECIFICATIONS
Accuracy: ±0,25% of rate
Output: 4-20 mA + HART or Fieldbus
Temperature process fluids: +427°C
Line size:
ANSI: Class 150 - Class 2500
DIN: PN10 - PN250
Certifications: Atex






For more information >>> Product Data SheetProduct Data Sheet
Fieldvue

3100

3100 SPECIFICATIONS
Measurement principle:
Ultrasonic, time-of-flight
Reference Accuracy: ±0.25% of measured distance
Measurement Range: 0,3 m to 11 m
Update interval: 1 second
Ambient Temperature: -40°C to +70°C
Temperature process fluids: -30°C to +70°C
Output: 4-20 mA + HART
Certification: Atex

For more information >>> Product Data SheetProduct Data Sheet
3100

3300

3300 SPECIFICATIONS
Reference Accuracy: ±5 mm for sensors < 5 m
Repeatability: ±1 mm
Measuring Range: 0,4 m to 23,5 m
Microwave Output Power:
Nominal: 50 µW
Max.: 2 mW
Start-up Time: <10 seconds
Output: 4-20 mA + HART
Ambient temperature limit: -40°C to +85°C
Temperature process fluids: -40°C to +400°C
Overpressure limit: 34,5 MPa
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet
3300

5300

5300 SPECIFICATIONS
Measurement Principle: Time Domain Reflectometry (TDR)
Microwave Output Power:
Nominal 300 µW, Max. 45 mW
Reference Accuracy: ±0.03% of measured distance
Update Interval: < 1 per second
Measuring Range: 0.4 m to 50 m
Ambient temperature limit: -40°C to +80°C
Temperature process fluids: -60°C to +400°C
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet'
5300

5401/5402

5401/5402 SPECIFICATIONS
Measurement Principle: Pulsed, free propagating radar
Frequency version:
5402: 26 GHz
5401: 6 GHz
Instrument Accuracy at reference conditions:
5402: ±3 mm
5401: ±10 mm
Maximum Measuring Range: 0.04 m to 35 m
Resolution: 1 mm
Ambient temperature limit: -40°C to +80°C
Temperature process fluids: 150°C
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet'
5401/5402

5600 5600

SPECIFICATIONS
Measurement Principle: Pulsed, free propagating radar
Frequency version: 10GHz
Instrument Accuracy at reference conditions: ±5 mm
Maximum Measuring Range: 0 m to 50 m
Resolution: 1 mm
Update Time: 100 ms
Ambient temperature limit: -40°C to +70°C
Temperature process fluids: -40°C to +400°C
Output: 4-20 mA + HART or Fieldbus
Certifications: Atex

For more information >>> Product Data SheetProduct Data Sheet

pemit en middle